summaryrefslogtreecommitdiff
path: root/init.d/halt.sh
blob: eabc8980f59b040201e3944eec9ee03d088a15f8 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
#!/bin/sh
# Copyright 1999-2007 Gentoo Foundation
# Distributed under the terms of the GNU General Public License v2

. /etc/init.d/functions.sh
. "${RC_LIBDIR}"/sh/rc-functions.sh

# Support LiveCD foo
if [ -r /sbin/livecd-functions.sh ] ; then
	. /sbin/livecd-functions.sh
	livecd_read_commandline
fi

stop_addon devfs
stop_addon udev

# Flush all pending disk writes now
sync ; sync

# If we are in a VPS, we don't need anything below here, because
#   1) we don't need (and by default can't) umount anything (VServer) or
#   2) the host utils take care of all umounting stuff (OpenVZ)
if [ "${RC_SYS}" = "VPS" ] ; then
	if [ -e /etc/init.d/"$1".sh ] ; then
		. /etc/init.d/"$1".sh
	else
		exit 0
	fi
fi

# If $svcdir is still mounted, preserve it if we can
if mountinfo "${RC_SVCDIR}" >/dev/null && [ -w "${RC_LIBDIR}" ]  ; then
	f_opts="-m -c"
	[ "${RC_UNAME}" = "Linux" ] && f_opts="-c"
	if [ -n "$(fuser ${f_opts} "${svcdir}" 2>/dev/null)" ] ; then
		fuser -k ${f_opts} "${svcdir}" 1>/dev/null 2>/dev/null
		sleep 2
	fi
	cp -p "${RC_SVCDIR}"/deptree "${RC_SVCDIR}"/softlevel \
		"${RC_SVCDIR}"/nettree "${RC_LIBDIR}" 2>/dev/null
	umount "${RC_SVCDIR}"
	rm -rf "${RC_SVCDIR}"/*
	# Pipe errors to /dev/null as we may have future timestamps
	cp -p "${RC_LIBDIR}"/deptree "${RC_LIBDIR}"/softlevel \
		"${RC_LIBDIR}"/nettree "${RC_SVCDIR}" 2>/dev/null
	rm -f "${RC_LIBDIR}"/deptree "${RC_LIBDIR}"/softlevel \
		"${RC_LIBDIR}"/nettree
	# Release the memory disk if we used it
	case "${mnt}" in
		"/dev/md"[0-9]*) mdconfig -d -u "${mnt#/dev/md*}" ;;
	esac
fi

unmounted=0
# Remount the remaining filesystems read-only
if [ "${RC_UNAME}" != "FreeBSD" ] ; then
	ebegin "Remounting remaining filesystems read-only"
	# We need the do_unmount function
	. "${RC_LIBDIR}"/sh/rc-mount.sh
	eindent
	do_unmount "mount -n -o remount,ro" "^(/dev|/dev/pts|/dev/shm|/proc|/proc/.*|/sys)$"
	eoutdent
	eend $?
	unmounted=$?
fi

# This UPS code should be moved to out of here and to an addon
if [ -f /etc/killpower ] ; then
	UPS_CTL=/sbin/upsdrvctl
	UPS_POWERDOWN="${UPS_CTL} shutdown"
elif [ -f /etc/apcupsd/powerfail ] ; then
	UPS_CTL=/etc/apcupsd/apccontrol
	UPS_POWERDOWN="${UPS_CTL} killpower"
fi
if [ -x "${UPS_CTL}" ] ; then
	ewarn "Signalling ups driver(s) to kill the load!"
	${UPS_POWERDOWN}
	ewarn "Halt system and wait for the UPS to kill our power"
	halt -id
	sleep 60
fi

if [ ${unmounted} -ne 0 ] ; then
	[ -x /sbin/sulogin ] && sulogin -t 10 /dev/console
	exit 1
fi

# Load the final script - not needed on BSD so they should not exist
[ -e /etc/init.d/"$1".sh ] && . /etc/init.d/"$1".sh

# Always exit 0 here
exit 0

# vim: set ts=4 :